HOME > Product Info > Regenerative.. |
|
|
 |
 |
|
Green Way Regenerative Fan Heater uses midnight electric power that is much cheaper than general electricity. It converts electricity into heat, keeps it in the regenerative system, and uses during daytime. The latest heating system, it is economical enough to save electric rates by a quarter. |
|
|
|
|
 |
¡Ý Clean heating |
It uses electricity as fuel so it doesn¡¯t make smoke. Accordingly it is clean compared with other heating systems. |
¡Ý Safe heating |
It is safe, having no phenomenon of lack of oxygen or no danger of explosion. |
¡Ý Economical heating |
A thermostat makes it possible to control the temperature of each room so there is no unnecessary fuel consumption. |
¡Ý Convenient heating |
It doesn¡¯t need space to keep fuel so it is installable even in small space. |
¡Ý Environmental pollution-free heating |
It doesn¡¯t cause lack of oxygen, dusts, or smell, and it doesn¡¯t contaminate air. Therefore, it is harmless to the human body. |
¡Ý Uses |
It is available for living rooms, bedrooms, or study rooms for students at home.
It is very suitable for heating offices, officetels, schools, hospitals, and other working areas.
It is very suitable, especially for repairing old heating systems in buildings.
|
|
|
 |
 |
Model No. |
GRA-240 |
GRA-320 |
GRA-400 |
GRA-480 |
GRA-530 |
GRA-600 |
GMA-1000 |
Power Consumption |
2.4KW |
3.2KW |
4.0KW |
4.8KW |
5.3KW |
6.0KW |
10.0KW |
Using Voltage |
1¨ª 220V or 3¨ª 380V |
Size of exterior housings
(WxDxH)mm |
781¡¿263
¡¿661 |
913¡¿263
¡¿661 |
1101¡¿263
¡¿661 |
1233¡¿263
¡¿661 |
1233¡¿263
¡¿747 |
1421¡¿263
¡¿747 |
1421¡¿263
¡¿1005 |
Type |
Compulsive Ventilation Type |
Time |
Time of Regenerative(10HR) |
Weight of Regenerative materials(kg) |
98 |
122 |
159 |
183 |
220 |
264 |
396 |
Gross Weight(kg) |
134 |
167 |
213 |
244 |
285 |
330 |
566 |
Effective regenerative capacity(Kcal/day) |
16,880 |
21,380 |
27,380 |
31,520 |
37,890 |
45,470 |
73,100 |
Heating Size (Pyeong) |
3~4 |
4~5 |
5~6 |
6~7 |
7~8 |
8~10 |
10~14 |
|
|
|
|
 |
Earth Leakage Circuit Breaker(E.L.B) |
Built-in(side) 1¥Õ30A, 3¥Õ15A |
Regenerative Capacity Controller |
1) Liquid Expanding type
2) Operating temperature: 240¢ªC~280¢ªC
3) 4 Step Control
0 : 0¢ªC (OFF)
I : 215¢ªC (33%)
II : 430¢ªC (66%)
III : 650¢ªC (100%) |
Anti-Overheating Device |
Bimetal type
Operating temperature : 100¢ªC~140¢ªC |
Blow Control Panel |
Bimetal type (Air temperature control) |
Blowhole |
Upward 45¢ª |
Room Thermostat |
1) Operating temperature : 0¢ªC ~34¢ªC
2) Sensor : Vapor Expansion Type |
|
|
|
|
 |
Exterior Housing |
o Materials : Electrolytic galvanized iron (1.0T pale yellow powder coating or beige hammer-tone coating)
o Temperature: Moderate temperature or below
|
Upper |
75¢ªC |
Right |
40¢ªC |
Front |
80¢ªC |
|
Down |
40¢ªC |
Left |
70¢ªC |
Back |
75¢ªC |
|
Regenerative Materials |
o Materials: Magnesia brick (MgO 85% or more)
o Specific heat : 0.265Kcal/Kg¢ªC
o Fire retardant temperature : 1920¢ªC |
Heating element |
o Materials: Incoloy pipe (11mm or shorter)
o Type: Sheath heater |
Insulation |
o Ceramic blanket
o Principal ingredient : Al2O3, SiO2, Fe2O3, TiO2, MgO, CaO...
o Thenotherm¡¯s principal ingredient : SiO2, TiO2, Al2O3
o Heat conductivity : 0.028 Kcal/mh¢ªC (660¢ªC) |
Insulation Cover |
o Materials: AL COT (Aluminum coating steel)
o To protect with cerakwool or cowl, prevent the scattering of lagging powder, and minimize natural radiation of heat. |
Blowhole |
o Materials: Corrosion-resistant electrolytic galvanized steel sheet |
Blow Control Panel |
o A control panel to mix hot air and indoor air in order to maintain the temperature of a blowhole at a moderate degree. |
FAN MOTOR |
o Features: 2 step speed control below 35dB (rpm : 850~1400)
o Type: Single-phase 220V, shading coil induction motor |
Shock Proof Plate |
o Materials: AL COT Steel Sheet (Mounted in the front)
o To protect the front insulation (Thenotherm) from external shock. |
|
|
|
|
|
|
|